Functional Description
EDU-409 List 1
January 26, 2000
 13
The capacities listed for the indoor enclosures in 
 assume no solar 
load. The capacities listed for the outdoor enclosures in 
 assume a full 
solar load as described above. The “Recommended Slot Assignment for 
Maximum Capacity” column assigns slots according to the following thermal 
stress reduction rules:
1
Always leave at least one empty slot between adjacent doublers. The 
adjacency rule only applies to the left- and right-hand sides of the 
doubler. The top of one unit can be adjacent to the bottom of another, 
though the latter configuration should be avoided if possible.
2
Allow as much room as possible between doublers on all four sides.
Rule 1 does not apply to the HRE-458 and HRE-819 enclosures 
since these products have the required slot separations 
already built into their design.
Slot assignments that do not follow the recommended 
configurations in 
 and 
 are permissible as long 
as the above two rules are applied. Otherwise, damage may 
occur to doubler units.
Table 5.
Indoor Enclosure Capacities
Vendor
Description
Model #
EDU-409 List 
1 Doubler 
Capacity
239 T1 
Repeater 
Capacity
CHARLES
Indoor wall mount
CiAC2300
7
7
CiAC2002
2
2
SPC
Indoor rack and wall 
mount
4400-09
18
18