ADC EDU-409 Manuel D’Utilisation

Page de 34
Overview
 
150-409-115-05, Issue 5
2
January 26, 2000
 EDU-409 List 1
A
PPLICATIONS
HiGain doublers operate with any number of T1, Plain Old Telephone 
Service (POTS), Digital Data Service (DDS), or other HiGain systems 
sharing the same cable binder group.
The EDU-409 List 1 has a range of up to 35 dB loss at 260 kHz on each of 
the four HDSL loops. A list of HDSL signal cable losses for various cable 
gauges at 260 kHz and 135 
Ω
 is provided in 
. The table is applicable 
to HDSL cable pairs running between the ELU and the EDU-409 List 1 and 
between the EDU-409 List 1 and another EDU or ERU.
The EDU-409 List 1 can be used in two-span to four-span circuits, depending 
on the models of the ELU and ERU being used with the doubler units and the 
power option chosen for the ERU. The number of doublers is equal to one less 
than the number of Spans (as shown in 
). 
Table 1.
HDSL Signal Cable Loss
Cable Gauge
Loss @ 260 kHz 
(dB/km)
(a)
Ω
 per km
0.4 mm/26 AWG
13.94
272
0.51 mm/24 AWG
10.47
171
0.61 mm/22 AWG
8.14
105
0.91 mm/19 AWG
5.74
52
(a) Add 3 dB for each bridged tap and 1 dB for each cable gauge change.