Solutions for common problems that may occur with the HDU-409 are listed 
in 
.
Table 9.
Fault Isolation Guide
Problem
Solution
LED does 
not light
Verify that the HLU is installed and operational in the CO.
Verify proper cabling between the doubler enclosure and the CO. 
Measure 100 to 200 Vdc between pins 5 or 6 and 8 or 9. This voltage 
peaks every 15 to 30 seconds as the HLU cycles between self test and 
line power. If less than 100 Vdc is present, check the cabling or the HLU. 
Only the line units mentioned in the “Applications” section can be used 
to power doublers (see 
). Other HLU models may not 
provide reliable operation and should not be used.
LED 
continues to 
flash green 
once a 
second
Synchronization is being attempted with the upstream unit.
HDU-409 
loses power
The HLU at the CO is not present. Measure the resistance of the HDSL input 
loop. Resistance should be normal loop resistance plus the 25
Ω
 signature 
of the HLU.
HDSL line 
power only 
appears in 
very short 
bursts
A grounded pair is being detected by either the HLU or HDU-409 in Span 1. 
This causes the unit’s GFD circuit to trigger which forces the HDSL line 
voltage off immediately after it cycles on. Remove the HLU and HDU-409 
and check for cable ground faults in Span 1. The doubler’s GFD circuit can 
easily be checked by grounding any of the loop connectors to the doubler. 
This forces the circuit down immediately. If the circuit stays up, either the 
GFD circuit is defective or the HDU-409 is not properly grounded.
HDU-409 
shuts off 
after Span 1 
comes up
A grounded pair is being detected by the HDU-409 in Span 2. Remove 
HDU-409 and check for ground fault in Span 2.