ADC UTU-701C Manuel D’Utilisation

Page de 82
700-701-100-02
 Functional 
Description
UTU-701 and ETU-751 List 1
August 9, 2002
 19
L
OOPBACKS
An HDSL system maintains several diagnostic loopback configurations, both toward and away from the local unit, 
which can be used to verify proper transmission of test data through the local unit, the HDSL facility, and the 
remote unit. 
 
on
 shows all possible loopback paths. 
 lists available loopbacks.
During loopbacks the system generates an Alarm Indication Signal (AIS) past the loopback point toward the far 
unit. Loopbacks can be activated from the LOC (local) and REM (remote) front-panel pushbuttons, the console 
Test menus, and the management unit interface. 
 lists loopback equivalents for different 
activation methods. Only one loopback option can be enabled at a time. During a loopback, the Loopback LEDs 
on the front panel indicate the type of loopback currently present in the system. See 
The system reverts to normal transmission of payload data after the specified timeout period has elapsed. If a 
timeout period is not specified, the loopback must be manually disengaged before normal transmission of data can 
resume.
Figure 8.
Loopback Operations
Table 11.
HDSL Transmission and Application Interface Alarms
Alarm
Description
HDSL Alarms
HDSL alarms include:
Margin (MAR)
Margin has fallen below threshold set for the HDSL interface.
Errored Seconds (ES)
Errored seconds count has exceeded threshold set for the HDSL interface.
Loss of Sync Word 
(LOSW)
Loss of sync word at the HDSL interface. Remains active during restart, but not a cold start.
G.703 Alarms
G.703 alarms include:
Loss of Signal (LOS)
Loss of signal at the G.703 input.
Loss of Frame Alignment 
(LFA)
Loss of frame alignment at the G.703 input.
Receive Alarm Indication 
Signal (AIS)
Alarm indication signal (unframed all ones) received at the G.703 input.
Remote Alarm Indication 
Signal (RAI)
Remote alarm indication signal received at the G.703 input (through A-bit). 
Loss of Clock (LOC)
Applies to loss of external clock when EXT timing is used. The external clock was lost for the 
previous second. This alarm is reset when the clock is active again.
Test loopbacks disrupt normal end-to-end transmission of customer data and are the 
equivalent of taking the circuit out of service. The circuit does not revert to normal operation 
until loopbacks are disengaged manually or until after the specified loopback timeout period 
has expired.
Nx64k
Nx64k
NTU Interface
LTU Interface
HDSL
HDSL
Single-pair
HDSL loop