Avaya S8500 Manuel D’Utilisation

Page de 72
Using the Avaya Remote Supervisor Adapter
ASM control
Avaya Remote Supervisor Adapter User Guide
27
November 2003
6
NMI Reset Delay [default: Disabled]: Use this field to specify the time in minutes that the RSA 
waits to restart the S8500 Media Server after a nonmaskable interrupt (NMI) generates. A NMI 
can be triggered by:
A critical error such as a hardware fault.
A parity error in the memory subsystem.
To set the NMI Reset Delay, select a value from the drop-down menu. To turn this option off, 
select Disabled.
7
Scroll to the bottom of the page and slick Save.
Setting ASM date and time 
Alerts that are sent from the RSA are time stamped using the RSA internal clock. The RSA internal clock 
uses Greenwich Mean Time (GMT) and Daylight Saving Time (DST) to enable administrators to manage 
servers that reside in different time zones. 
To set the date and time:
1
In the navigation pane, select System Settings under the ASM Control heading. 
The ASM Date and Time window appears (see 
Figure 5: ASM date and time
2
Scroll down to the ASM Date and Time section and click Set ASM Date and Time.
The ASM Date and Time window opens (see 
Figure 6: ASM Date and Time