Avaya S8500 Manuel D’Utilisation

Page de 72
Using the Avaya Remote Supervisor Adapter
Alerts
38
Avaya Remote Supervisor Adapter User Guide
November 2003
Setting local events 
To set the events:
1
In the navigation pane, select Event Log under the Monitors heading.
The Monitored Local Events window appears (see 
38).
Figure 15: Monitored local events
 on page 38 for an explanation of monitored local alerts.
Table 6: Monitored local events  1 of 2
Event
Action
Event log 75% full
[default: Enabled]: Generates an event if the event log reached 75% of 
capacity.
Event log full
[default: Enabled]: Generates an event if the event log reaches capacity. 
When the event log reaches capacity, the oldest entries in the log are 
deleted by new entries.
Redundant power supply 
failure
Not used on the S8500 Media Server configuration.
Voltage irregularity
[default: Enabled]: Generates an event if the monitored voltages exceed 
their thresholds.
Power off
[default: Enabled]: Generates an event if the power to the S8500 Media 
Server is turned off.
  1 of 2