HP laserjet m712 Guide De Dépannage
![HP](https://files.manualsbrain.com/attachments/29005dca542c93ad59e01e223583dbd51961550d/common/fit/150/50/3931a36faa9f1af0627fe52b73d277ccf98e5d18c55433f253353db13ee5/brand_logo.jpeg)
The DC controller determines if the motor has failed and notifies the formatter when the motor
encounters the following conditions:
●
Startup failure — The motor does not reach a specified rotational count within a specified time
from when the motor starts.
●
Rotational failure — The rotational speed of the motor is not in the specified range for a specified
time after the motor reaches a specified speed.
The DC controller notifies the formatter of a BD (beam detect) failure when it detects a rotational failure
of the scanner motor.
The DC controller monitors the related part condition of the following motors to determine a motor
failure:
●
Upper cassette lifter motor
●
Lower cassette lifter motor
Fan control
The product has three fans for preventing the temperature from rising in the product and cooling down
the delivered paper.
8
Chapter 1 Theory of operation
ENWW