kymco mo p250 Instruction De Maintenance

Page de 10
10
. A.C. GENERATOR/STARTER CLUTCH
10-3
PEOPLE 250
RIGHT CRANKCASE COVER
REMOVAL
Disconnect the water hoses from the water
pump cover. (!chapter 5)
Disconnect the water hoses from the right
crankcase cover.
Remove the nine bolts attaching the right
crankcase cover and the cover.
Remove right crankcase cover.
RIGHT CRANKCASE COVER
REMOVAL(ENGINE INSTALLED)
Remove met-in box and frame body cover.
(!2-6)
Disconnect the water hoses from the water
pump cover. (!chapter 5)
Disconnect the water hoses from the right
crankcase cover. (!chapter 5)
Disconnect A.C. generator wire coupler and
oil pressure switch wire. (!chapter 5)
Remove the eight bolts attaching the right
crankcase cover and the cover.
Remove the left and right rear shock absorber
lower mount bolts. (!chapter 5)
Elevate the back of engine as possible by
placing a suitable stand under the back of
engine.
Remove the bolt between water pump cover
and oil filter screen cap.
Remove right crankcase cover.
STATOR REMOVAL
Remove the two pulser coil attaching screws
and the pulser coil.
Remove the three A.C. generator stator bolts
and the stator.
Water  Hose
Bolts
Water  Pump  Cover
Screws
Bolts
Pulser Coil
A.C.  Generator Stator
Bolts
When removing the pulser coil and
stator, be careful not to damage them to
avoid shorted or broken wire.
Bolt
Water  Pump  Cover
Oil Filter Screen Cap
Support the machine securely so there is
no danger of it falling over.