kymco mo movie125150 Instruction De Maintenance

Page de 12
14
. BATTERY/CHARGING SYSTEM/
A.C. GENERATOR
14-2
TORQUE VALUES
Pulser coil bolt
0.5kg-m
Coil lock bolt
0.9kg-m
Flywheel nut
5.5kg-m
Cooling fan bolt
0.9kg-m
SPECIAL TOOLS
Universal holder
Flywheel puller
TESTING INSTRUMENTS
Kowa electric tester
Sanwa electric tester
TROUBLESHOOTING
No power
Intermittent power
• Dead battery
• Loose battery cable connection
• Disconnected battery cable
• Loose charging system connection
• Fuse burned out
• Loose connection or short circuit in
• Faulty ignition switch
lighting system
Low power
Charging system failure
• Weak battery
• Loose, broken or shorted wire or connector
• Loose battery connection
• Faulty regulator/rectifier
• Charging system failure
• Faulty A.C. generator
• Faulty regulator/rectifier
Charging indicator light does not come on
• Dead battery
• Faulty charging indicator
• Faulty indicator light bulb
Charging indicator light does not go out
• Faulty  battery
• Faulty charging indicator
• Faulty regulator/rectifier