kymco mo x500 Instruction De Maintenance

Page de 19
20
. LIGHTS/METERS/SWITCHES
 
20-14
   XCITING 500
INSPECTION
Connect the fuel unit wire connectors and turn
the ignition switch “ON”.
Check the fuel meter for correct indication by
moving the fuel unit float up and down.
Float Position
Display
Upper
Much (Full)
Lower
Less (Empty)
Wire Terminals
Display
Free
From Much to Less
Apply
From Less to Much
The fuel meter is normal if it operates as above
indicated. If not, check for poorly connected
terminals or shorted wires.
INSTALLATION
Install the O-ring and fuel unit.
Before performing the following test,
operate the turn signals to determine that
the battery circuit is normal.
Align the groove on the fuel unit with
the flange on the fuel tank.
                   Groove
                                          Flange
                 
Lower
                 
Upper