kymco mo x500 Instruction De Maintenance

Page de 19
20
. LIGHTS/METERS/SWITCHES
     
20-17
   XCITING 500
BANK ANGLE SENSOR
INSPECTION
Support the scooter level surface.
Remove the meter panel (page 2-13).
Turn the ignition switch to “ON” and measure
the voltage between the following terminals of
the bank angle sensor connector with the
connector connected.
TERMINAL
STANDARD
Black/Blue
Battery voltage
Black/White
Battery voltage – (0-1 V)
The engine should stop as you incline the bank
angle sensor approximately degrees to the left or
right.
REMOVAL/INSTALLATION
Disconnect the bank angle sensor connector.
Remove the two screws, washers and bank angle
sensor.
Bank Angle Sensor
Bank Angle         Sensor Screws/Washers