Enterasys Networks 4H4202-72 Manuel D’Utilisation

Page de 90
COM Port Pinout Assignments
Enterasys Matrix DFE-Gold Series Modules Hardware Installation Guide A-3
COM Port Pinout Assignments
The COM port is a serial communications port for local access to Local Management. 
Refer to 
 for the COM port pin assignments.
Environmental
Operating Temperature
5°C to 40°C (41°F to 104°F)
Storage Temperature
-30°C to 73°C (-22°F to 164°F)
Operating Relative Humidity
5% to 90% (non-condensing)
Table A-1 Specifications (continued)
Item
Specification
Table A-2 COM Port Pin Assignments
Pin
Signal Name
Input/Output 
1
Transmit Data (XMT)
Output
2
Clear to Send (CTS)
Input
3
Data Set Ready (DSR)
Input
4
Receive Data (RCV)
Input
5
Signal Ground (GND)
NA
6
Request to Send (RTS)
Output
7
Data Terminal Ready (DTR)
Output
8
Data Carrier Detect (DCD)
Input