Allied Telesis AT-8000S Manuel D’Utilisation

Page de 188
Viewing Statistics
Managing RMON Statistics
Page 165
  
Absolute — Compares the values directly with the thresholds at the end of the sampling interval.
Rising Threshold — Displays the rising counter value that triggers the rising threshold alarm. The rising 
threshold is presented on top of the graph bars. Each monitored variable is designated a color.
Rising Event — Displays the mechanism in which the alarms are reported. The possible field values are: 
LOG — Indicates there is not a saving mechanism for either the device or in the management system. If 
the device is not reset, the entry remains in the Log Table. 
TRAP — Indicates that an SNMP trap is generated, and sent via the Trap mechanism. The Trap can also 
be saved using the Trap mechanism. 
Both — Indicates that both the Log and Trap mechanism are used to report alarms.
Falling Threshold — Displays the falling counter value that triggers the falling threshold alarm. The falling 
threshold is graphically presented on top of the graph bars. Each monitored variable is designated a color.
Falling Event — Displays the mechanism in which the alarms are reported. 
Startup Alarm — Displays the trigger that activates the alarm generation. Rising is defined by crossing the 
threshold from a low-value threshold to a higher-value threshold.
Interval (sec) — Defines the alarm interval time in seconds.
Owner — Displays the device or user that defined the alarm.
2.
Click Create. The Add Alarm Page opens: 
Figure 109:Add Alarm Page
3.
Define the Interface, Counter Name, Sample TypeRising ThresholdRising EventFalling Threshold, Falling 
Event
, Startup Alarm, Interval, and Owner fields.
4.
Click Apply. The RMON alarm is added, and the device is updated.
To modify RMON alarms: 
1.
Click Statistics > Alarm. The RMON Alarm Page opens.