blockage of venting system. When using snow blowers, 
make sure snow is not directed towards vent termina-
tion area.
The TDV series is considered a “special vent system”.  
Check with local codes or in the absence of same, with 
CSA B149.1 installation codes regarding special vent 
termination clearances.
NOTICE:  Flexible and rigid vent system components 
are not interchangable unless otherwise specified in the 
venting instructions.
NOTICE:  Additional venting information regarding 
clearances, terminal locations, and safety information is 
contained in the installation and operationg instructions 
packaged with the appliance.
3³⁄₈" (86mm)
7⁷⁄₈"
(200mm)
8"
(203mm)
9¹⁄₈"
(232mm)
T193
offset and rise elbows
12/5/03  djt
TDV45S 45° 
Elbow
90° Elbow
B
A
T194
vent offset
12/5/03  djt
Vent Offset @ 45°
T193
45°
 
 
Installed
  Vent Pipe 
True Length 
“A” 
“B”
  Component 
Gain 
Rise 
Run
 
TDV6 
4”  
2¹¹⁄₁₆” 
2¹¹⁄₁₆” 
 
 
(102mm) 
(68mm) 
(68mm)
 
TDV12 
10” 
7¹⁄₁₆” 
7¹⁄₁₆” 
 
 
(254mm) 
(179mm) 
(179mm)
 
TDV18 
16” 
11⁵⁄₁₆” 
11⁵⁄₁₆” 
 
 
(406mm) 
(287mm) 
(287mm)
 
TDV36 
34” 
24¹⁄₁₆” 
24¹⁄₁₆” 
 
 
(864mm) 
(611mm) 
(611mm)
 
TDV48 
46” 
32¹⁄₂” 
32¹⁄₂”
 
 
(1168mm) 
(826mm) 
(826mm)
T194
IMPORTANT: Do not mix vent system compo-
nents with components for other vent systems.
NOTE:  Use only venting systems and components 
as certified with the appliance. Use of uncertified vent 
systems or components will void the warranty and may 
compromise the operation of the fireplace, its systems, 
and components as certified with the appliance. Use 
of uncertified vent systems or components will void the 
warranty and may compromise the operation of the 
fireplace.
Through the Roof (Vertical) Venting
When the venting penetrates a roof the system must be 
insalled in accordance with the current CSA B149.1 in-
stallation code (in Canada) or the current National Fuel 
Gas Code, ANSI Z223.1/NFPA 54 (in U.S.A.).  SEE 
CHART FOR VERTICAL TERMINATION LOCATION.
Elbows & Offsets - General
Each installation assures the use of one 45° elbow hori-
zontal or vertical (off top of unit).
Sidewall (Horizontal) Venting Information
1.  Make sure fireplace location and termination location 
are consistent with requirements for terminations 
and vent runs.
2.  Secure unit to the floor.
3.  Locate vent opening in wall. Maintain 2” (51 mm) 
clearance to top of vent from combustibles. Install 
wall thimble per instructions supplied with Horizontal 
Vent Kit.  Refer to Page 14, Figures 19 and 20 for 
wall thimble installation.
4.  Attach vent components beginning with a TDV45S 
elbow. Apply high temperature sealant to the out-
side leading edge of the fireplace flue pipe, then 
install the TDV45S starter elbow and secure it to the 
fireplace with the three (3) screws (provided) through 
the outer pipe flange and into the fireplace 7” (178 mm) 
dia. starter flange.
T196
Horizontal takeoff
12/5/03  djt
Screw Location
Apply Sealant 
to Flue Pipe
Horizontal 
Take Off 
Illustrated
T196
Fig. 27  Apply high temperature sealant to outside of the flue 
pipe.