Temco DV1000/1200/1400 Series
76657
5.  Drywall can be extended flush on the bottom, top 
and to the outermost part of the sides of the fire-
place.
6.  Noncombustible materials such as brick and tile 
can be extended across the face of the fireplace.  If 
brass trim kit is going to be installed, brick and tile 
will have to be installed flush with the front of this 
appliance.
Clearance to Combustibles
Top of unit to ceiling* ................................36” (914 mm)
Front of unit to combustibles ....................36” (914 mm)
Appliance
 
Top (from standoffs)  .................................0” (0mm)
 
Bottom  ......................................................0” (0mm)
 
Side (from standoffs) .................................0” (0mm)
 
Back (from standoffs) ................................0” (0mm)
 
Top of Elbow ...........................................2” (51mm)
* Ceiling height is the minimum height of the room ceiling in front of 
the fireplace measured from the top front edge of the fireplace.
Combustible Sidewall Clearance
The perpendicular combustible sidewall or mantel sup-
port leg (surround) clearance is 1³⁄₄” (45mm) from the 
edge of the recessed door opening.
Mantels
The height that a combustible mantel is fitted above the 
fireplace is dependent on the depth of the mantel. 
For the correct mounting height and widths, refer to 
Figure 5.
Noncombustible mantels and legs may be installed at 
any height and width around the appliance. When using 
paint or lacquer, it must be heat resistant to prevent 
discoloration. 
WARNING:  Combustible objects must not be placed 
on a noncombustible mantel unless the noncombustible 
mantel meets the minimum height and width require-
ments for a combustible mantel.
Surround Material
When using materials around the face of the fireplace, 
these materials must be suitable to withstand the tem-
peratures which they will encounter.  Also these materi-
als must not extend out in front of the face of the unit, in 
effect recessing the unit.
If the material used for surround is not flush with the 
face of the unit, then the optional surround kits will not 
fit properly.
It is recommended that any material used to surround 
the face of the fireplace be noncombustible (i.e. ceram-
ic tile, brick, natural stone, etc.). Combustible materials 
such as drywall, are permissible.
A B C D E
V
W
X
Y
Z
Fireplace
T177
Temco DV Mantel 
Chart
12/3/03  djt
Top of Louvre 
Opening
Mantel Chart
 
 
Mantel Shelf 
 
Mantel from Top
 
Ref.  or Breast Plate  Ref.  of Louvre Opening 
 
 
Depth
 
10” (254 mm) 
14” (356 mm)
 
8” (203 mm) 
12” (305 mm)
 
6” (152 mm) 
10” (254 mm)
 
4” (101 mm) 
8” (203 mm)
 
2” (51 mm) 
6” (152 mm)
T177
Fig. 5  combustible mantel minimum installation.
T178
surround material
12/3/03  djt
Drywall
Tile, Marble, etc.
Drywall
Fireplace 
Front
Tile, 
Marble, 
etc.
Optional 
Surround 
Kits
Fireplace 
Front
Noncombustible Facing 
Material Overlap of Front Face
Flush Face Installation 
(Recommended when 
installing optional trim 
surround kits)
T178
Fig. 6  Surround material options.
Materials such as cultured marble or other synthetic 
materials are not recommended as they may discolor, 
warp or create odor as a result of exposure to the tem-
peratures of the front of the fireplace.