Drain Connection
Figure 23 and Figure 24 show typical drain trough and 
drain line installations.
Connect the drain outlet to a vented drain system using 
only a flexible connection. The drain system must be 
vented to prevent an air lock or siphoning. 
Use the supplied black rubber adapter and clamps to 
transition from the machine drain outlet to the 2 inches 
schedule 40 PVC plumbing (20 and 30 models) and 
the 3 inches schedule 40 PVC plumbing (40, 60, 80 
and 125 models).
If proper drain size is not available or practical, a surge 
tank is required. A surge tank along with a sump pump 
should be used when gravity drainage is not possible, 
such as in below-ground-level installations.
Figure 23 
Figure 24 
CHM2058N
1
Drain Hose
5
Floor
2
Drain Valve
6
Open Drain Trough
3
Overflow Hose
7
1 in. Minimum Gap
4
Drain Tee
CHM2058N
CHM2058N
1
2
3
4
5
7
DRAIN TROUGH
6
CHM2335N
1
Drain Hose
4
Overflow Hose
2
Drain Valve
5
Vent Pipe*
3
Drain Tee
6
Trap (as required by local codes)
* Drain line must be vented to meet local plumbing codes.