160 Series Drive Control Logic Chart
The following truth table (Tables 26 - 30) designates 
the preset speed selection based on the inputs to the 
control terminals. A disconnected control terminal will 
seek the high signal voltage condition (greater than 
10V DC). 
To activate a control input (i.e., SW1, SW2, etc.), the 
terminal is connected to a common terminal (TB3-3 or 
TB3-7) to lower the signal voltage to a low condition 
(less than 1 Volt DC).
Pocket Hardmount
V Control and A control
H – Control Voltage High (greater than 10V DC)
L – Control Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
SW3
SW2
SW1
STF
Stop
STR
Preset Status –
Parameter 15
Input Status –
Parameter 12
DC Volt Meter Red Probe Terminal Location
4
2
1
6
8
5
DC Volt Meter Black Probe Terminal Location
3
3
3
3
3
3
Action
Frequency 
Preset 
Parameter #
Terminal 
#4 
(SW3)
Terminal 
#2
(SW2)
Terminal 
#1 
(SW1)
Terminal 
#6
(STF)
Terminal 
#8 
(Stop)
Terminal 
#5
(STR)
Not Us
ed
SW
3
SW
2
SW
1
Not Us
ed
ST
F
St
o
p
STR
Idle
N/A
H
H
H
H
L/H
H
0
0
0
0
0
0
0/1
0
1/2 Wash Speed Forward
62
H
H
L
L
H
0
0
0
1
0
1
1
0
1/2 Wash Speed Reverse
62
H
H
L
H
L
0
0
0
1
0
0
1
1
Wash Speed Forward
63
H
L
H
L
H
0
0
1
0
0
1
1
0
Wash Speed Reverse
63
H
L
H
H
L
0
0
1
0
0
0
1
1
Distribution Speed
65
L
H
H
L
H
0
1
0
0
0
1
1
0
Spin 1
64
H
L
L
L
H
0
0
1
1
0
1
1
0
Spin 2
67
L
L
H
L
H
0
1
1
0
0
1
1
0
Spin 3
66
L
H
L
L
H
0
1
0
1
0
1
1
0
Pocket Hardmount
WE-6 Control - Design 5 and Earlier
H – Control Voltage High (greater than 10V DC)
L – Control Voltage Low (less than 1V DC)
0 = No signal received
1 = Signal received
SW3
SW2
SW1
STF
Stop
STR
Preset Status –
Parameter 15
Input Status –
Parameter 12
DC Volt Meter Red Probe Terminal Location
4
2
1
6
8
5
DC Volt Meter Black Probe Terminal Location
3
3
3
3
3
3
Action
Frequency 
Preset 
Parameter #
Terminal 
#4 
(SW3)
Terminal 
#2
(SW2)
Terminal 
#1 
(SW1)
Terminal 
#6
(STF)
Terminal 
#8 
(Stop)
Terminal 
#5
(STR)
Not U
s
ed
SW3
SW2
SW1
Not U
s
ed
STF
St
o
p
STR
Idle
N/A
H
H
H
H
L/H
H
0
0
0
0
0
0
0/1
0
1/2 Wash Speed Forward
65
L
H
H
L
H
0
1
0
0
0
1
1
0
1/2 Wash Speed Reverse
65
L
H
H
H
L
0
1
0
0
0
0
1
1
Wash Speed Forward
63
H
L
H
L
H
0
0
1
0
0
1
1
0
Wash Speed Reverse
63
H
L
H
H
L
0
0
1
0
0
0
1
1
Distribution Speed
62
H
H
L
L
H
0
0
0
1
0
1
1
0
Medium Extract/Spray Rinse
67
L
L
H
L
L
H
0
1
1
0
0
1
1
0
High 1 Extract
66
L
H
L
L
L
H
0
1
0
1
0
1
1
0
High 2 Extract
64
H
L
L
L
L
H
0
0
1
1
0
1
1
0
High 3 Extract
68
L
L
L
L
L
H
0
1
1
1
0
1
1
0
Table 26