Cabling the System
2-11
2
2. Enterprise 6000/5000 systems only: route the terminal cable from the clock
board down along the right mounting rail of the cabinet.
Use tie wraps to secure the terminal cable to the mounting rail.
3. Connect the terminal power cord into an AC wall outlet.
4. Configure the ASCII terminal as follows:
9600 bps
1 stop bit
8 data bits
Parity off
Full duplex
Refer to the instruction manual shipped with the terminal for specific
configuration instructions.
Note – The setup parameters listed in Step 4 may differ from the setup at the
customer site. These parameters can be changed in the NVRAM. Refer to the
s
et-defaults
and
printenv
commands in the OpenBoot Command Reference
manual, part number 802-3242.
2.7 Connecting the Fiber Cable to the I/O Board
1. Remove the two plastic caps that cover the cable connector on the FC/OM
module.
2. Remove the plastic cap covering the ends of the fiber cable.
3. Connect one end of the fiber cable into the FC/OM module installed on
the I/O board.
Align the notch in the cable connector with the key notch in the module
connector. See Figure 2-11.
4. Connect the other end of the fiber cable into the FC/OM connector on the
SPARCstorage Array (or other storage device with fiber optics interface)
rear panel.
Align the notch in the cable connector with the notch in the connector on the
storage device rear panel.