ACS 50 Manuel D’Utilisation

Page de 63
6.  Re-install the heater and heater plate assemblies in reverse order. Install new heater 
gaskets and securely tighten all fasteners. 
Heater loops should not touch each other.  “Hot Spots” lead to 
premature heater failure! 
7.  Reinstall the wires based on the sketch you made earlier. 
8.  Secure the heater access cover. 
 
6-7   Replacing the Regeneration Heater 
The dehumidifying dryers use heater elements located below each desiccant bed. 
 
Disconnect and lock out power before you replace heater elements! 
1.  Remove the cover plate secured by bolts. 
2.  Sketch the heater wiring configuration so you can properly re-assemble the heaters. 
3.  Remove the wiring for the heater being removed or replaced. 
4.  Remove the bolts securing each heater mounting plate.  Slide out the heater. 
5.  Re-install the new heaters in reverse order.  Install new heater gaskets and securely 
tighten all fasteners. 
Heater loops should not touch each other.  “Hot Spots” lead to premature 
heater failure! 
6.  Re-install the wiring based on the sketch you made earlier. 
7.  Secure the heater access cover. 
 
 
 
Operation 
56