Chapter 7:  Troubleshooting 
Problem 
Possible cause 
Corrective action 
Little or no air coming from 
the process delivery tube. 
Dirty filter. 
Clean or replace filter. 
Desiccant beds are 
contaminated by material or 
plasticizer leaking into the 
system. 
Replace desiccant. 
Blower overload has tripped. 
Fix the problem and reset the 
overload. 
Blower fins filled with dust or 
contaminants. 
Remove blower side plate, 
clean baffles, replace. 
Suction in delivery tube, 
pressure from the return 
tube. 
Phase is reversed on power 
drop coming into the dryer. 
Stop the dryer. 
 
If the dryer was connected to 
the drying hopper, check to 
see if the desiccant and 
process air heater has been 
contaminated with resin. 
 
If so, replace the desiccant 
and remove any resin carry-
over. Otherwise, change the 
phase of two legs of the 
three-phase power drop. 
Loss or reduction of process 
air temperature. 
Process heaters are faulty. 
Check for open heaters. 
Replace if required. 
Solid-state temperature 
controller faulty. 
Replace. 
Process temperature was 
adjusted in error by plant 
personnel. 
Make sure that plant 
personnel are aware of the 
proper temperature set point. 
A sign posted next to the 
controller is helpful. 
Loss or reduction in drying 
capacity. 
Process heaters are faulty. 
Replace. 
Desiccant beds are 
contaminated. 
Replace desiccant. 
Material being dried differs 
from material specified at the 
time of purchase. 
Drying systems are designed 
for the material which was 
originally specified. Different 
materials may need a longer 
residence time or different 
drying temperature. 
Break in flex hose to/from 
drying hopper. 
Inspect for air leaks; replace 
if necessary. 
 
 
 