Interface timing
The figure below shows the timing for the parallel interface.
B U S Y
d
lop 
D A T A
 
STROBE
Initialization
The printer can be initialized (returned to a fixed set of conditions) in
three ways:
Hardware
initialization
Software
initialization
Control
panel
initialization
 The power is turned on.
 The printer receives an INIT signal from the parallel
interface (pin   goes LOW).
The following condition then results:
 The printer mechanism is initialized.
 The input data buffer is cleared.
 The download character set is cleared.
 The print buffer is cleared.
 The default values are set. (Panel settings are reset.)
 Software sends the 
   (initialize the printer)
command.
The following condition then results:
 The print buffer is cleared.
 The default values are set. 
 last panel settings are
kept.)
 Hold down the RESET button.
 The printer switches to an interface using the Auto
interface selection feature.
The following results:
 The input data buffer is cleared.
 The print buffer is cleared.
 The default values are set. (The last panel settings are
kept.)