Cisco 11500 Series Content Services Switch Hardware Installation Guide
78-13884-03
Appendix C      Troubleshooting
Troubleshooting the CSS 11501
Troubleshooting the CSS 11501
CSS 11501 status is indicated by the Status LED on the front panel. For 
information about the CSS 11501 LEDs, refer to Chapter 2, 
.
 provides suggestions for correcting problems that may occur with the 
CSS 11501. 
Table C-4
Troubleshooting the CSS 11501
Symptom
Recommended Action
At boot up, the following 
message appears:
CHMGR: Slot slot/subslot 
had diagnostic failures - 
NOT STARTING UP
When there is a failure on a CSS 11501 
component, the CSS 11501 attempts the boot 
process three times. If the boot is unsuccessful, 
the CSS generates a log message and saves it in 
the boot.log file. Obtain technical assistance. 
Refer to th
. For 
information on log files, see 
During normal CSS operation, 
the following message appears:
Temperature has reached x 
celsius for slot number
Check the six fans in the chassis. The 
CSS 11501 is running at a temperature that is 
too high, as indicated by the variable. When a 
fan failure occurs, obtain technical assistance.