5.1 
Cleaning
Regular cleaning will extend the life and performance of the CX-70DHD. Before cleaning, 
be sure to unplug the power cord from the power outlet.
Cleaning the Display 
Panel Body and Remote 
Control
Do not under any circumstances use solvents such as benzene or thinner to clean the 
CX-70DHD. Doing so may cause deterioration or peeling of paint from the display or 
remote control unit.
Wipe the display and remote control gently with a soft cloth. In the case of excessive dirt 
buildup, dampen a soft cloth with a diluted neutral cleaning detergent and after wringing 
the cloth thoroughly, wipe the component and then dry it with a dry soft cloth.
Cleaning the Screen
After dusting, wipe the screen gently using the supplied cleaning cloth or another soft 
cloth (cotton, flannel etc.). Do not use tissue or a rough cloth. The screen surface is easily 
scratched; do not rub it or hit it with a hard object.
If you clean the surface of the screen with a wet cloth, water droplets on the surface may 
enter into the product and cause a malfunction.
Cleaning the Vents
As a general rule, use a vacuum cleaner about once a month to clean the vents on the 
rear panel of the display of dust buildup (set the vacuum cleaner to its weakest setting 
when doing this). If not removed, accumulated dust can cause the internal temperature to 
increase, resulting in possible breakdown or fire.
5.2 
Troubleshooting Tips
Table 5-1 provides some general guidelines for troubleshooting problems you may 
encounter with the CX-70DHD. If the suggested solutions fail to resolve the problem or if 
you encounter an issue not described here, please contact your Runco dealer or Runco 
Technical Support.  
5. Maintenance and Troubleshooting
Table 5-1. Troubleshooting Chart 
Symptom
Possible Cause(s)
Solution
The display does not turn on 
after initial installation. 
• The CX-70DHD is not 
plugged in or the AC outlet 
is not active. 
• The DHD Controller is not 
plugged in or the AC outlet 
is not active. 
 
• The  remote  control 
batteries have run out. 
• The serial connection from 
the DHD Controller to the 
CX-70DHD is incorrect. 
• Ensure that the CX-70DHD 
is plugged in and that the 
AC outlet is active. 
• Ensure that the DHD 
Controller is plugged in 
and that the AC outlet is 
active. 
• Replace the batteries. 
 
• Ensure that the RS-232 
(Display Control) output 
from the DHD Controller is 
properly connected to the 
RS-232C input on the 
CX-70DHD (see Figure 3-4 
or Figure 3-5).