Installation
Models IWF033, IWF040, IWF055 and 
IWF075 (2-speed)
Surface
The machine must be securely fixed on a flat surface 
(metal base, concrete or solid ground). The anchoring 
is to be done on the 4 provided places in the holes on 
the corner of the base. (See Mounting Bolt Hole 
Figure 21 
The machine must be placed entirely level. For easy 
maintenance it is recommended to keep a minimal 
distance of 23.62 in. (600 mm) between the wall and 
the back of the machine.
If several machines are placed next to each other, there 
should be a minimal distance of 1.18 in. (30 mm) 
between each machine.
Anchoring to Metal Base
The machines must be fixed on a metal base which is 
securely anchored on a concrete base. Refer to 
Figure 22 
Machine bolts should be re-checked on a quarterly 
basis.
CHM2102N
1
Mounting Bolt Holes
Ensure that the machine is installed on a 
level floor of sufficient strength and that 
the recommended clearances for 
inspection and maintenance are provided. 
Never allow the inspection and 
maintenance space to be blocked.
SW020
CAUTION
CHM2102N
1
CHM2103N
1
Machine Base 
2
Nut 
.625 in. (M16) 
3
Washer 
1.57 in. x 0.60 in. x 0.15 in. 
(40 mm x 17 mm x 4 mm)
4
Bolt
.625 in. x 2.5 in. (M16x60 mm) 
5
Bolt
.625 in. (M16) 
6
Concrete Base 
15.74 in. (400 mm) (Models IWF033 and 
IWF040), and 21.65 in. (550 mm) 
(Model IWF055), and 27.55 in. (700 mm) 
(Model IWF075)
7
Metal Base
CHM2103N
1
2
3
7
4
6
2
3
5