Q-Logic 8200 Manuel D’Utilisation

Page de 170
2–Configuring NIC
NIC TroubleShooting/Diagnostics
2-74
SN0054671-00  B
Running Linux User Diagnostics
Linux user diagnostics include QConvergeConsole diagnostics and ethtool 
diagnostics.
QConvergeConsole Diagnostics
QConvergeConsole CLI-based diagnostics include the following commands: 
To enable or disable the port beacon, issue the following command: 
qaucli -pr nic -beacon [cna_port_inst] <on|off> 
To run an internal loopback test, issue the following command: 
qaucli -pr nic -intloopback <cna_port_inst> <tests_num
<on_error
>
where 
tests_num
 is the number of tests (1–65535) and 
on_error
 is either 
0=Ignore
 or 
1=Abort
To perform a Flash test, issue the following command: 
qaucli -pr nic testflash [cna_port_inst]
To perform a hardware test, issue the following command: 
qaucli -pr nic -testhw [cna_port_inst] 
To perform an interrupt test, issue the following command: 
qaucli -pr nic -testinterrupt [cna_port_inst] 
To perform a link test, issue the following command: 
qaucli -pr nic -testlink [cna_port_inst] 
To perform a register test, issue the following command:
qaucli -pr nic -testregister [cna_port_inst]
NOTE:
Information on installing and starting the GUI version of QLogic's 
QConvergeConsole utility is provided in the QConvergeConsole User's 
Guide
. All procedural information for that utility is covered in the 
QConvergeConsole Help System