Q-Logic 8200 Manuel D’Utilisation

Page de 170
2–Configuring NIC
NIC TroubleShooting/Diagnostics
2-76
SN0054671-00  B
Link Test verifies that the port is linked, meaning that the port has a good 
cable attached to the port and that other end of the cable is connected to an 
operational Ethernet port, either another NIC port or a network device, such 
as a switch. 
Register Test verifies the NIC register read and write. 
Linux Diagnostic Test Messages
Test information and PASS or FAIL messages are displayed for each of the tests 
listed in 
QLogic Device Windows Property Page Diagnostics
This section covers the following information for user diagnostics for Windows NIC 
driver management applications:
Running Windows User Diagnostics
You can run user diagnostics using either the QConvergeConsole GUI or the CLI.
To run user diagnostics in the GUI:
1.
Access the Windows Control Panel, and then open the Device Manager
2.
In the Device Manager, right-click the QLogic 10Gb Ethernet adapter, and 
then on the shortcut menu, click Properties
NOTE:
Information on installing and starting the GUI version of QLogic's 
QConvergeConsole utility is provided in the QConvergeConsole User's 
Guide
. All procedural information for that utility is covered in the 
QConvergeConsole Help System