INSTALLATION
Continued
Minimum Clearances For Side Combustible 
Material, Side Wall and Ceiling 
A.  Clearances from the side of the fireplace 
cabinet to any combustible material and 
wall should follow diagram in Figure 4.
 
Example: The face of a mantel, bookshelf, 
etc. is made of combustible material and 
protrudes 3 
1
/
2
" from the wall. This com-
bustible material must be 4" from the side 
of the fireplace cabinet (see Figure 4).
 
Note: When installing your gas logs into 
a  manufactured  firebox,  follow  firebox 
manufacturer’s instructions for minimum 
clearances to combustible materials.
B.  Clearances from the top of the fireplace 
opening to the ceiling should not be less 
than 42".
NOTICE: Manual control heaters 
may be used as a vented product. 
If so, you must always run heater 
with chimney flue damper open. 
If  running  heater  with  damper 
open,  noncombustible  material 
above  fireplace  opening  is  not 
needed. Go to Installing Damper 
Clamp  Accessory  for  Vented 
Operation, page 12.
LOG SIZING REQUIREMENTS
Log 
Size
Minimum Firebox
Height Depth
Front 
Width
Rear * 
Width
18"
17"
14"
24"
20"
24"
17"
14"
28"
21"
30"
17"
14"
34"
24"
* Measured at 14" depth.
Figure 4 - Minimum Clearance for 
Combustible to Wall 
*Minimum 16 inches from Side Wall 
*
Example
Minimum Noncombustible Material 
Clearances 
If Not Using Mantel
Note: If using  a mantel  proceed  to If Using 
Mantel, page 11. If not using a mantel, follow 
the information on this page. 
You  must  have  noncombustible  material(s) 
above the fireplace opening. Noncombustible 
materials (such as slate, marble, tile, etc.) must 
be at least 1/2 inch thick. With sheet metal, you 
must  have  noncombustible  material  behind 
it.  Noncombustible  material  must  extend  at 
least 8" up (for all models). If noncombustible 
material  is  less  than  12",  you  must  install 
the  fireplace  hood  accessory  (24"  and  30" 
Models  Only).  See  Figure  5  for  minimum 
clearances.
Noncombustible  
Material Distance 
(A)
Requirements for Safe 
Installation
12" or more
Noncombustible material 
okay.
Between 8" and 
12"
24" or 30" Models: Install 
fireplace hood accessory 
(GA6050, GA6052 or 
GA6053 see Accesso-
ries
, page 31).
18" Model: Noncombus-
tible material okay. 
Less than 8"
Noncombustible material 
must be extended to at 
least 8". See Between 
8" and 12"
, above. If you 
cannot extend material, 
you must operate heater 
with flue damper open.
Figure 5 - Heat Resistant Material (Slate, 
Marble, Tile, etc.) Above Fireplace