 WARNING: Before installing 
in a solid fuel burning fireplace, 
the chimney flue and firebox must 
be  cleaned  of  soot,  creosote, 
ashes and loose paint by a quali-
fied chimney cleaner. Creosote 
will ignite if highly heated. A dirty 
chimney flue and firebox may cre-
ate and distribute soot within the 
house. Inspect chimney flue for 
damage. If damaged, repair flue 
before operating heater.
  WARNING:  Seal  any  fresh 
air vents or ash clean-out doors 
located on floor or wall of fire-
place. If not, drafting may cause 
pilot  outage  or  sooting.  Use  a 
heat-resistant  sealant.  Do  not 
seal chimney flue damper.
 WARNING: Never install the 
heater
•  in  a  bedroom  or  bathroom 
unless  installed  as  a  vented 
appliance, see page 12
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing  or  other  flammable 
objects  are  less  than  36" 
from  front  and  42"  from  top 
of heater; for side clearances 
see Figure 4, page 10
•  in high traffic areas
•  in windy or drafty areas
INSTALLATION
Continued
 CAUTION: This heater cre-
ates  warm  air  currents.  These 
currents move heat to wall sur-
faces  next  to  heater.  Installing 
heater next to vinyl or cloth wall 
coverings  or  operating  heater 
where impurities (such as, but 
not limited to, tobacco smoke, 
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in 
the air exist, may discolor walls 
or cause odors.
IMPORTANT: Vent-free heaters add moisture 
to the air. Although this is beneficial, installing 
heater  in  rooms  without  enough  ventilation 
air may cause mildew to form from too much 
moisture. See Air for Combustion and Ventila-
tion
, page 6.
CHECK GAS TYPE
Use the correct gas type (natural or propane/
LP) for your unit. If your gas supply is not cor-
rect, do not install log set. Call dealer where 
you bought log set for proper type fireplace.
 WARNING: This appliance is 
equipped for either natural gas 
or propane/LP gas but not both. 
Gas type is indicated on the rat-
ing plate. Field conversion is not 
permitted.
INSTALLATION AND CLEARANCES 
FOR VENT-FREE OPERATION
  WARNING:  Maintain  the 
minimum clearances. If you can, 
provide greater clearances from 
floor, ceiling and adjoining wall.
MINIMUM FIREPLACE CLEARANCE TO 
COMBUSTIBLE MATERIALS
Side Wall 16", Ceiling 42", Front 36"
Carefully  follow  these  instructions.  This  will 
ensure safe installation into a masonry, UL127-
listed manufactured fireplace or listed vent-free 
firebox.