Belkin f5d7000ce2 Manuel D’Utilisation

Page de 29
Report No.: RM920221R04A
14
Issued: Mar. 14, 2003
Reference No.: RM920221R04
The phenomena allowed during and after test in each criterion are clearly stated in
the following table
Performance criteria
Criteria
During test
After test
A
Shall operate as intended.
May show degradation of
performance (see note1).
Shall be no loss of function.
Shall be no unintentional
transmissions.
Shall operate as intended.
Shall be no degradation of
performance (see note 2).
Shall be no loss of function.
Shall be no loss of stored data or
user programmable functions.
B
May show loss of function (one or
more).
May show degradation of
performance (see note 1).
No unintentional transmissions.
Functions shall be self-
recoverable.
Shall operate as intended after
recovering.
Shall be no degradation of
performance (see note 2).
Shall be no loss of stored data or
user programmable functions.
C
May be loss of function (one or more). Functions shall be recoverable
by the operator.
Shall operate as intended after
recovering.
Shall be no degradation of
performance (see note 2).
NOTE 1:Degradation of performance during the test is understood as a degradation to a level
not below a minimum performance level specified by the manufacturer for the use of
the apparatus as intended. In some cases the specified minimum performance level
may be replaced by a permissible degradation of performance.
If the minimum performance level or the permissible performance degradation is not
specified by the manufacturer then either of these may be derived from the product
description and documentation (including leaflets and advertising) and what the user
may reasonably expect from the apparatus if used as intended.
NOTE 2: No degradation of performance after the test is understood as no degradation below a
minimum performance level specified by the manufacturer for the use of the
apparatus as intended. In some cases the specified minimum performance level may
be replaced by a permissible degradation of performance. After the test no change of
actual operating data or user retrievable data is allowed.
If the minimum performance level or the permissible performance degradation is not
specified by the manufacturer then either of these may be derived from the product
description and documentation (including leaflets and advertising) and what the user
may reasonably expect form the apparatus if used as intended.