Belkin f5d7000ce2 Manuel D’Utilisation

Page de 29
Report No.: RM920221R04A
16
Issued: Mar. 14, 2003
Reference No.: RM920221R04
5.4  ELECTROSTATIC DISCHARGE IMMUNITY TEST (ESD)
5.4.1 TEST SPECIFICATION
Basic Standard:
EN 61000-4-2
Discharge Impedance:
330 ohm / 150 pF
Discharge Voltage:
Air Discharge - 8 kV (Direct)
Contact Discharge – 4kV (Direct/Indirect)
Polarity:
Positive & Negative
Number of Discharge:
Minimum 20 times at each test point
Discharge Mode:
Single Discharge
Discharge Period:
1 second minimum
5.4.2 TEST INSTRUMENT
DESCRIPTION &
MANUFACTURER
MODEL NO.
SERIAL NO.
CALIBRATED
UNTIL
KeyTek, ESD Simulator
MZ-15/EC
9902287
Feb. 26, 2003
EM Test ESD Simulator
ESD 30C
0201-28
Jul. 15, 2003
EM Test ESD Discharge Unit
P30C
0201-28
Jul. 15, 2003
EM Test ESD Discharge Unit
P30C-RFCI
0601-07
Jul. 15, 2003
FCC Coupling Decoupling
Network
FCC-801-T2
020022
Jun.12, 2003
FCC Coupling Decoupling
Network
FCC-801-T4
020033
Jun.12, 2003
NOTE: 1. The test was performed in ESD Room No. 1.
2. The calibration interval of the above test instruments is 12 months and the
    calibrations are traceable to NML/ROC and NIST/USA.