Furuno back gp-80 Manuel D’Utilisation

Page de 101
  7 – 3
7.3 Ship’s Speed Alarm
The ship’s speed alarm sounds when ship's
speed is lower or higher (or within) the alarm
range set.
1) Press [MENU ESC] and [4].
2) Press ▲ or ▼ to select Ship Speed.
3) Press t or s to select In (or Over).
In: Alarm sounds when speed is within
range set.
Over: Alarm sounds when speed is higher
or lower than range set.
4) Press ▼ to select Speed Range.
5) Key in low speed.
6) Key in high speed.
7) Press the [NU/CU ENT] key.
8) Press the [MENU ESC] key.
When speed is higher or lower (or within) than
the speed set here, the buzzer sounds and the
message "Speed alarm" appears. You can si-
lence the audible alarm by pressing the
[CLEAR] key. To erase the visual alarm, press
the [CLEAR] key again.
To disable the alarm, select Off at step 3.
7.4 Trip Alarm
The trip alarm sounds when the distance run
is greater than the trip alarm setting.
1) Press [MENU ESC] and [4].
2) Press  ▲  or  ▼ to select Next Page. The
menu shown in Figure 7-6 appears.
Figure 7-6 Alarm settings menu, page 2/2
3) Press ▲ or ▼ to select Trip.
4) If necessary, press [CLEAR] to reset the
trip distance and trip elapsed time (see
page 6-1).
5) Press t or s to select On.
6) Press ▼ to select Trip Range.
7) Key in trip range.
8) Press the [NU/CU ENT] key.
9) Press the [MENU ESC] key.
When the ship's distance run is higher than
the trip range set here, the buzzer sounds and
the message "Trip alarm" appears. You can
silence the audible alarm by pressing the
[CLEAR] key. To erase the visual alarm, press
the [CLEAR] key again.
ALARM SETTINGS              2/2
To Previous Page
                                     On        Off
           Trip Range        0123.00nm
Water Temp.                   In         Over     Off
      Temp. Range         +12.0 ~ +15.0
°
C
Depth                              In         Over     Off
      Depth Range          0003.0 ~ 0200.0ft
DGPS Alarm
           On       Off
 Trip (CLR:Reset)     
Off
Off
MENU : Escape
:  Select