Figure 5 - Ventilation Air from Outdoors
ventilation Air From Outdoors
Provide  extra  fresh  air  by  using  ventilation 
grills or ducts. You must provide two perma-
nent openings: one within 12" of the ceiling 
and one within 12" of the floor. Connect these 
items directly to the outdoors or spaces open 
to the outdoors. These spaces include attics 
and crawl spaces. Follow the National Fuel 
Gas  Code, ANSI  Z223.1/NFPA  54, Air  for 
Combustion and Ventilation for required size 
of ventilation grills or ducts.
IMPORTANT:  Do  not  provide  openings  for 
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering 
the attic will activate the power vent.
 WARNING: A qualified ser-
vice person must install firebox. 
Follow all local codes.
  WARNING:  Never  install 
firebox
•  in a bedroom or bathroom*
•  in a recreational vehicle
•  where  curtains,  furniture, 
clothing, or other flammable 
objects are less than 36" from 
front or 42" from top of fire-
box. For side clearances see 
Figure 6, page 11
•  in high traffic areas
•  in windy or drafty areas
* Unless installed log set is rated 
at 10,000 Btu/hr or less.
  CAUTION:  Log  heaters 
installed  in  this  firebox  create 
warm air currents. These currents 
move heat to wall surfaces next 
to firebox. Installing firebox next 
to vinyl or cloth wall coverings or 
operating firebox where impuri-
ties (such as, but not limited to, to-
bacco smoke, aromatic candles, 
cleaning fluids, oil or kerosene 
lamps, etc.) in the air exist, may 
discolor walls or cause odors.
INsTAllATIoN
NOTICE: The firebox identifica-
tion label (including model num-
ber, serial number, clearances, 
etc.) is located on a chain under 
the bottom refractory.
IMPORTANT: Vent-free gas log heaters add 
moisture to the air. Although this is beneficial, 
installing  firebox  in  rooms  without  enough 
ventilation air may cause mildew to form from 
too much moisture. See, page 8.
IMPORTANT: Make sure the firebox is level. 
If  firebox  is  not  level,  log  set  will  not  work 
properly.
Note: Your firebox is designed to be used in 
zero clearance installations. Wall or framing 
material can be placed against any exterior 
surface on the rear, sides, top or bottom of 
your firebox, except where standoff spacers 
are integrally attached. If standoff spacers are 
attached to your firebox, these spacers can 
be placed directly against wall or framing ma-
terials. Use the dimensions shown for rough 
opening to create the easiest installation.
Use  dimensions  shown  for  rough  openings 
to create the easiest installation (see Built-In 
Firebox Installation, page 12).
AIr For CoMBUsTIoN ANd VeNTIlATIoN
Continued
Outlet
Air
Ventilated
Attic 
Outlet
Air
Inlet
Air
Inlet Air
Ventilated 
Crawl Space
To 
Crawl
Space
To Attic