SAFETY
Continued
12. This heater needs fresh, outside air ven-
tilation to run properly. This heater has an 
oxygen depletion sensing (ODS) pilot light 
safety system. The ODS shuts down the 
heater if not enough fresh air is available. 
See Air for Combustion and Ventilation
page 6. If heater keeps shutting off, see 
Troubleshooting, page 24.
13. Do not run heater
• where flammable liquids or vapors are 
used or stored
• under dusty conditions
14. Do not use this heater to cook food or burn 
paper or other objects.
15. Do not use heater if any part has been ex-
posed to or under water. Immediately call 
a qualified service technician to inspect 
the room heater and to replace any part 
of the control system and any gas control 
which has been under water.
16. Do not operate heater if any log is broken. 
Do not operate heater if a log is chipped 
(dime-sized or larger).
17. Turn heater off and let cool before servic-
ing, installing, or repairing. Make sure the 
selector switch is in the OFF position. Only 
a qualified service person should install, 
service, or repair heater.
18. Make  sure  the  selector  switch  is  in  the 
OFF  position  when  you  are  away  from 
home for long periods of time.
19. This heater must not be connected to any 
external electrical source.
20. Operating  heater  above  elevations  of 
4,500 feet could cause pilot outage.
21. Provide adequate clearances around air 
openings.
22. Keep  burner  and  control  compartment 
clean.
23. Solid fuels shall not be burned in a fire-
place in which an unvented room heater 
is installed.
4.  If you smell gas
• shut off gas supply
• do not try to light any appliance
• do not touch any electrical switch; do not 
use any phone in your building
• immediately call your gas supplier from 
a  neighbor’s  phone.  Follow  the  gas 
supplier’s instructions
• if  you  cannot  reach  your  gas  supplier, 
call the fire department
5.  This  heater  shall  not  be  installed  in  a 
bedroom or bathroom unless installed as 
a vented appliance (see Installing Damper 
Clamp Accessory for Vented Operation

page  11).  This  gas  log  set  may  not  be 
installed as a vented appliance in a bed-
room or bathroom in the Commonwealth 
of Massachusetts.
6.  Before installing in a solid fuel burning fire-
place, the chimney flue and firebox must 
be cleaned of soot, creosote, ashes and 
loose paint by a qualified chimney cleaner. 
Creosote will ignite if highly heated. A dirty 
chimney  flue  may  create  and  distribute 
soot  within  the  house.  Inspect  chimney 
flue for damage. If damaged, repair flue 
and firebox before operating heater.
7.  Do  not  burn  solid-fuel  in  a  masonry  or 
UL127  factory-built  fireplace  in  which  a 
vent-free room heater is installed.
8.  If fireplace has glass doors, never operate 
this heater with glass doors closed. If you 
operate  heater  with  doors  closed,  heat 
buildup inside fireplace will cause glass to 
burst. Make sure there are no obstructions 
across openings of fireplace.
9.  This log heater is designed to be smoke-
less. If logs ever appear to smoke, turn off 
heater and call a qualified service person. 
Note: During initial operation, slight smok-
ing  could  occur  due  to  log  curing  and 
heater burning manufacturing residues.
10. To prevent the creation of soot, follow the 
instructions in Cleaning and Maintenance, 
page 23.
11. Before using furniture polish, wax, carpet 
cleaner, or similar products, turn heater 
off. If heated, the vapors from these prod-
ucts may create a white powder residue 
within burner box or on adjacent walls or 
furniture.