iii. Installing the Q53
Site Requirements
iii
I
NSTALLING
 
THE
 Q53
This chapter describes the following:
Site Requirements
Prepare to install the Q53 in a clean, well-ventilated environment protected from 
extremes of temperature, humidity, mechanical shock, or vibration. Provide enough 
space at the front and back of the unit for cable connections.
Depending upon the specific options selected at time of ordering, the Q53 may be 
powered from a 115 or 230 VAC outlet using the supplied external transformer through 
a output cord to a barrel-style power connector, or over the Ethernet cable (Power Over 
Ethernet - POE) from an Ethernet switch providing power as defined in the IEEE 
standard 802.11af. If using the external AC transformer, prepare to install the Q53 within 
four meters (13 feet) of a grounded 115 or 230 VAC outlet.
The Q53 must be installed within RF range of the local Zigbee wireless PAN, in order to 
connect to the PAN and therefore bridge it over the TCP/IP network to the remote PAN. 
The maximum distance from the Q53 to the nearest Zigbee PAN node will vary 
depending upon the installation environment and capabilities of the other Zigbee 
node(s).
The Q53 is an intentional radiator of Radio Frequency (RF) energy. In order to limit RF 
exposure to personnel in the immediate area, the Q53 should be located and installed 
such that a separation of at least 20 centimeters is maintained between the Q53’s antenna 
and personnel in the vicinity of the device.
Note:
ESD precautions should be used when attaching or removing the antenna.