3. Installing the Q53
Site Requirements
Site Requirements
3
I
NSTALLING
THE
Q53
This chapter describes the following:
•
•
•
Site Requirements
Prepare to install the Q53 in a clean, well-ventilated environment protected from
extremes of temperature, humidity, mechanical shock, or vibration. Provide enough
space at the back of the unit for cable connections.
extremes of temperature, humidity, mechanical shock, or vibration. Provide enough
space at the back of the unit for cable connections.
Depending upon the specific options selected at time of ordering, the Q53 may be
powered from a 115 or 230 VAC outlet using the supplied external transformer through
a output cord to a barrel-style power connector, or over the Ethernet cable (Power Over
Ethernet - PoE) from an Ethernet switch providing power as defined in the IEEE standard
802.11af. If using the external AC transformer, prepare to install the Q53 within four
meters (13 feet) of a grounded 115 or 230 VAC outlet.
powered from a 115 or 230 VAC outlet using the supplied external transformer through
a output cord to a barrel-style power connector, or over the Ethernet cable (Power Over
Ethernet - PoE) from an Ethernet switch providing power as defined in the IEEE standard
802.11af. If using the external AC transformer, prepare to install the Q53 within four
meters (13 feet) of a grounded 115 or 230 VAC outlet.
The Q53 must be installed within RF range of the local ZigBee wireless PAN, in order
to connect to the PAN and therefore bridge it over the TCP/IP network to the remote
PAN. The maximum distance from the Q53 to the nearest ZigBee PAN node will vary
depending upon the installation environment and capabilities of the other ZigBee
node(s).
to connect to the PAN and therefore bridge it over the TCP/IP network to the remote
PAN. The maximum distance from the Q53 to the nearest ZigBee PAN node will vary
depending upon the installation environment and capabilities of the other ZigBee
node(s).
The Q53 is an intentional radiator of Radio Frequency (RF) energy. In order to limit RF
exposure to personnel in the immediate area, the Q53 should be located and installed
such that a separation of at least 20 centimeters is maintained between the Q53’s antenna
and personnel in the vicinity of the device.
exposure to personnel in the immediate area, the Q53 should be located and installed
such that a separation of at least 20 centimeters is maintained between the Q53’s antenna
and personnel in the vicinity of the device.
Note:
ESD precautions should be used when attaching or removing the antenna.