Generac Power Systems 0G6019 Manuel D’Utilisation

Page de 12
 4 
INSTALLATION
For easier installation, the batteries should first be 
fitted into the display unit (Figure 1). This will allow 
you to walk around and find the best location for the 
unit while still receiving good signal strength. Attach 
the other transceiver to the generator and mount it as 
high as possible, preferably away from any structures 
to get a maximum signal.
Figure 1 — Open Display Unit
1.  Insert the batteries (Figure 2).
Figure 2 — Insert Batteries
2.  Connect the generator end transceiver and ensure 
it is turned on.
3.  IMMEDIATELY turn on the display, one minute 
will pass while the generator tries to find it’s dis-
play.
4.  The display will show that it is searching for the 
generator and the yellow LED may flash occasion-
ally as it receives data from the generator trans-
ceiver. This is due to the unit searching for the 
correct channel.
5.  Once the generator is found, the radio link is now 
setup and the settings will be remembered next 
time the display unit is turned on. If the genera-
tor is not found, an error message will briefly be 
shown, and the yellow LED will flash at one (1) 
second intervals to indicate the display unit was 
unable to find the generator.
6.  If the battery power to the generator (and there-
fore the end transceiver) is ever disconnected, the 
radio link will need to be reset. See the section 
titled “Reset Radio”.
7.  If the generator is not talking to it’s transceiver, 
but the radios are talking to each other, this will 
be indicated by an appropriate alarm which will 
be displayed after a 30 second period. Check the 
wiring and connection to the generator.
8.  Place the display at the preferred location. Do not 
permanently mount it yet.
9.  Plug the wall transformer into the display so as 
not to use up the batteries. Familiarize personnel 
with the radio menu (by reading the manual in 
conjunction with operating the display).
10. Navigate the display to show the “Radio 
Information” screen from the radio menu.
11. Monitor the signal strength and relocate the dis-
play if the signal strength is poor or non existent. 
The signal strength display is only updated if the 
unit can communicate, (which occurs every two 
(2) seconds), and will be set to display zero if the 
unit cannot communicate within a ten (10) sec-
ond period.
12. Mount the display using the holes on the back to 
hang onto two suitably sized fixing screws in the 
drywall 2¼ inches apart. It should be vertically 
mounted on a wall BETWEEN studs for maxi-
mum signal strength (Figure 3).
Figure 3 — Mounting Holes