4.3 General performance data
After the device is powered up or reset, the unit (Tx and Rx) starts operating. Within specified
performance the sensor readings are within <3s. In Table 4-1 the general performance data
are given.
performance the sensor readings are within <3s. In Table 4-1 the general performance data
are given.
Table 4-1: General performance data
Environmental
Ambient Temperature
-40 ... +85
degree C
Shock
100
g
rms
Vibration
14
g
rms
IP
67
Pressure / Transport altitude
0…10.000
m
Mechanical
Weight
340
g
Dimensions
See 5.2
Housing Identification
05
Antenna Identification
2C
DSP Board Identification
11
General
Power Supply
8 ... 32
I
<5
II
V DC
W
W
Frequency Band
24.075…24.175
GHz
Bandwidth
< 100
MHz
Max. Transmit Power (EIRP)
20.0
dBm
Interfaces
CAN V2.0b (passive)
RS485 full duplex
10/100 Ethernet
10/100 Ethernet
I
measured at connector
II
Power consumption at 20°C.