sms smart microwave sensors GmbH UMRR112C Manuel D’Utilisation

Page de 16
 
CONFIDENTIAL AND PROPRIETARY 
The Information contained in this document shall remain the sole exclusive property of s.m.s, smart microwave sensors GmbH and shall not 
be disclosed by the recipient to third parties without prior consent of s.m.s, smart microwave sensors GmbH in writing. 
 
9_UMRR-11 Type 44 User Manual USA CAN_100MHz.docx   I   Page 6 of 16   I  January 24, 2018 
 
4.3  General performance data 
After the device is powered up or reset, the unit (Tx and Rx) starts operating. Within specified 
performance the sensor readings are within <3s. In Table 4-1 the general performance data 
are given. 
Table 4-1: General performance data 
Environmental 
 
 
Ambient Temperature 
-40 ... +85
 
degree C 
Shock 
100
 
g
rms
 
Vibration 
14
 
g
rms
 
IP 
67 
 
Pressure / Transport altitude 
0…10.000 
 
Mechanical 
 
 
Weight 
340 
Dimensions 
 
Housing Identification 
05
 
 
Antenna Identification 
2C 
 
DSP Board Identification 
11 
 
General 
 
 
Power Supply 
8 ... 32
 I
 
<5
II
 
V DC 
Frequency Band 
24.075…24.175 
GHz 
Bandwidth 
< 100
 
MHz 
Max. Transmit Power (EIRP) 
20.0 
dBm 
Interfaces 
CAN V2.0b (passive) 
RS485 full duplex 
10/100 Ethernet 
 
 
 
I
 measured at connector 
II
 Power consumption at 20°C.