Selex ES SPA F567DHDE-HP Manuel D’Utilisation

Page de 60
 
SELEX Communications 
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
41
 
   July 2010 
 
 
I/O Socket block B2L male pinout
 
type contact 
 
out 
power supply alarm (*) 
out 2 
temperature 
alarm 
(*) 
out 
synchronization alarm (*) 
out 
RF power alarm (*) 
in 1 
not 
used 
in 2 
not 
used 
in 3 
not 
used 
in 4 
not 
used 
in A1 
not 
used 
in A2 
not 
used 
 
 
(*) The meaning of the digital outputs depends on the firmware release of the RBS. 
In the shown example the meaning is as follows: 
9
  Output 1: power supply alarm. When the RBS is supplied from battery the output is closed. 
9
  Output 2: RBS temperature alarm. When the temperature is over a defined maximum value the 
output is closed. 
9
  Output 3: RBS synchronization alarm. When the RBS loses synchronisation the output is closed. 
9
  Output 4: RF power alarm. When the PA transmitting power is 3 dB below the right power level the 
output is closed.