I/O Socket block B2L male pinout
type contact
out
1
power supply alarm (*)
out 2
temperature
alarm
(*)
out
3
synchronization alarm (*)
out
4
RF power alarm (*)
in 1
not
used
in 2
not
used
in 3
not
used
in 4
not
used
in A1
not
used
in A2
not
used
(*) The meaning of the digital outputs depends on the firmware release of the RBS.
In the shown example the meaning is as follows:
9
Output 1: power supply alarm. When the RBS is supplied from battery the output is closed.
9
Output 2: RBS temperature alarm. When the temperature is over a defined maximum value the
output is closed.
9
Output 3: RBS synchronization alarm. When the RBS loses synchronisation the output is closed.
9
Output 4: RF power alarm. When the PA transmitting power is 3 dB below the right power level the
output is closed.