Selex ES SPA F567DHDE-HP Manuel D’Utilisation
SELEX Communications
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed
by SELEX Communications S.p.A. in writing
48
July 2010
Red
Vin fail
Input voltage out of range
2
Green
Vout ok
RBS internal voltage levels are correct
Red
Vout fail
RBS internal voltage failure
3
Green
Control bus busy
Activity on the control bus
Red
Control bus fail
control bus among the modules is in failure
Red
blink
blink
Control bus fail
Bad message received
4
Green
Upload
Firmware upload in progress
Red
Upload fail
Firmware upload failed
7.1.4 DC/DC module
The DC/DC module is a continue power voltage converter from an external
power source to the internal power level of ECOS-D devices. The converter,
other than the power voltage conversion, is able to galvanically insulate
(1500Vrms) the internal 12Vdc power distribution from the external power
source and a 28Vdc power distribution to the 110W PA module.
7.1.5 Synchronization module - SYNC
The "Synchronization” (SYNC) module is the module that is able to manage network
synchronisation for ECOS-D equipment. This module is equipped with devices for numerical
computation (DSP, FPGA) and control (microprocessor) combined with the electrical
interfaces to the GPS antenna.
The extreme versatility of this module allows you to synchronize the ECOS-D RBS using
different reference sources.
The module is able to receive the input reference source from multiple clock signals:
• Internal GPS receiver
• AF tone (eg, tone at 3400 Hz via from an external source through LIF or DIF
module)