Selex ES SPA F567DHDE-HP 사용자 설명서

다운로드
페이지 60
 
SELEX Communications 
Information contained in this document may not be used, applied or reproduced for any purpose unless agreed 
by SELEX Communications S.p.A. in writing
 
48
 
   July 2010 
 
 
 
Red 
Vin fail 
Input voltage out of range 
Green
  
Vout ok 
RBS internal voltage levels are correct 
 
Red 
Vout fail 
RBS internal voltage failure 
Green
 
Control bus busy 
Activity on the control bus 
 
Red 
Control bus fail 
control bus among the modules is in failure 
 
Red 
blink 
Control bus fail 
Bad message received 
Green
 
Upload 
Firmware upload in progress 
 
Red 
Upload fail 
Firmware upload failed 
7.1.4 DC/DC module 
The DC/DC module is a continue power voltage converter from an external 
power source to the internal power level of ECOS-D devices. The converter, 
other than the power voltage conversion, is able to galvanically insulate 
(1500Vrms) the internal 12Vdc power distribution from the external power 
source and a 28Vdc power distribution to the 110W PA module. 
 
 
 
 
 
7.1.5  Synchronization module - SYNC 
The "Synchronization” (SYNC) module is the module that is able to manage network 
synchronisation for ECOS-D equipment. This module is equipped with devices for numerical 
computation (DSP, FPGA) and control (microprocessor) combined with the electrical 
interfaces to the GPS antenna. 
The extreme versatility of this module allows you to synchronize the ECOS-D RBS using 
different reference sources. 
The module is able to receive the input reference source from multiple clock signals: 
• Internal GPS receiver 
•  AF tone (eg, tone at 3400 Hz via from an external source through LIF or DIF 
module)