4. Commissioning 
 
MF0150A2A.doc
            
 
                   Manual for ION-
M7P/85P/17EP/19P
Page 39
 
The Mains cable is part of the delivery. It’s available in two wiring configurations: 
 
Prot ect ive Cap
 
Wiring 1 
Pin Name  Color 
1 Phase Black 
2 Neutral White 
3 n.c.  n.c 
PE Ground  Green 
Wiring 2 
Pin Name 
Color 
1 Phase 
Brown 
2 Neutral 
Blue 
3 n.c. 
n.c 
PE Ground
Green/Yellow 
table 4-2 AC power cable pinning 
 
For the AC power supply connection, a minimum cross section of 1.5 
mm
2
 is required. Each wire must observe the applicable national 
regulations regarding loop impedance, voltage drop, and methods of 
installation. Make sure to connect the correct voltage to the unit. 
 
Note:  
Do not connect or disconnect the power cord at the mains connector while 
power is on. Turn off mains* power before connecting the power cord at 
the Remote Unit, then, engage mains again. 
*   Mains power must be interrupted with an external mains breaker. For the mains breaker, observe 
the following recommendation:
 
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the 
external AC breaker should be 20 Amps max. for 120-Volt service or 13 - 16 Amps for 240-Volt 
service. 
 
4.2.11.2.  Mains power connection DC 
 
Caution: Danger of electrical hazard by high current. Disconnect mains 
power before opening the DC connector housing.
 
Note: The Mains cable must be properly secured observing local regulations and 
electrical codes. Be sure to allow enough slack in the cable at the RU to mount or 
dismount the cable into the DC Mains connector of the RU.