Andrew Wireless System M78517E19P Manuel D’Utilisation
4. Commissioning
MF0150A2A.doc
Manual for ION-
M7P/85P/17EP/19P
Page 39
The Mains cable is part of the delivery. It’s available in two wiring configurations:
Prot ect ive Cap
Wiring 1
Pin Name Color
1 Phase Black
2 Neutral White
3 n.c. n.c
2 Neutral White
3 n.c. n.c
PE Ground Green
Wiring 2
Pin Name
Color
1 Phase
Brown
2 Neutral
Blue
3 n.c.
n.c
PE Ground
Green/Yellow
table 4-2 AC power cable pinning
For the AC power supply connection, a minimum cross section of 1.5
mm
mm
2
is required. Each wire must observe the applicable national
regulations regarding loop impedance, voltage drop, and methods of
installation. Make sure to connect the correct voltage to the unit.
installation. Make sure to connect the correct voltage to the unit.
Note:
Do not connect or disconnect the power cord at the mains connector while
power is on. Turn off mains* power before connecting the power cord at
the Remote Unit, then, engage mains again.
power is on. Turn off mains* power before connecting the power cord at
the Remote Unit, then, engage mains again.
* Mains power must be interrupted with an external mains breaker. For the mains breaker, observe
the following recommendation:
120 Volt / 20 Amp max. or 240 Volt / 16 Amp, single-phase, 50 / 60 Hz AC service is needed, i.e. the
external AC breaker should be 20 Amps max. for 120-Volt service or 13 - 16 Amps for 240-Volt
service.
external AC breaker should be 20 Amps max. for 120-Volt service or 13 - 16 Amps for 240-Volt
service.
4.2.11.2. Mains power connection DC
Caution: Danger of electrical hazard by high current. Disconnect mains
power before opening the DC connector housing.
power before opening the DC connector housing.
Note: The Mains cable must be properly secured observing local regulations and
electrical codes. Be sure to allow enough slack in the cable at the RU to mount or
dismount the cable into the DC Mains connector of the RU.
electrical codes. Be sure to allow enough slack in the cable at the RU to mount or
dismount the cable into the DC Mains connector of the RU.