4. Commissioning 
 
MF0150A2A.doc
            
 
                   Manual for ION-
M7P/85P/17EP/19P
Page 41
 
 
First, install a conduit fitting (not 
contained in scope of delivery) to the 
34.52 mm hole. This must be a suitable 
fitting for a 1 Inch conduit with lock nut.  
Inside, the clearance around the hole is 
5 mm, the maximum space for the nut is 
8 mm. Then, insert your wiring through 
the opening and mount it to the M6 mains 
terminals. Observe the correct polarity. 
Close the conduit fitting to ensure water 
tightness. For strain release, two M5 
threaded holes are provided; the distance 
between the threaded holes is 34.5 mm. 
 
Mount the housing cover by inserting it 
into the recess at the repeater cabinet 
and fastening the two M3 x 12 captive 
screws. 
 
 
Attention:  For the DC power supply connection, a minimum cross section of 
6.6 mm
2
  (≤ AWG 9) per potential is required. Each wire must 
observe the applicable national regulations regarding loop 
impedance, voltage drop, and methods of installation. Make sure 
to connect the correct voltage to the unit. To ensure water-
tightness of the unit, use the correct size of cable gland. 
Note:  
Do not connect or disconnect the power cord at the mains connector while 
power is on. Turn off mains* power before connecting the power cord at 
the Remote Unit, then, engage mains again. 
*   Mains power must be interruptible with an external mains breaker (40 A). For the mains breaker, 
observe the local regulations of the DC provider.
 
 
+