Technology Solutions Ltd 1153 Manuel D’Utilisation

Page de 28
1153 UHF Reader User Guide V1.23
© Technology Solutions (UK) Ltd 2014
23
MAINTENANCE
TROUBLESHOOTING
For trouble-free service please observe the following tips when using the 1153 UHF Reader:
 
Protect the 1153 UHF Reader from temperature extremes. Do not leave it on the dashboard of a car on a hot
day, and keep it away from heat sources.
TROUBLESHOOTING AND MAINTENANCE
Symptoms
Possible cause
Action
Nothing happens when the yellow 
button is pressed.
If the LEDs are not on then the 
battery may be flat.
Charge the 1153 UHF Reader. 
The 1153 UHF Reader may have 
button actions disabled.
Check the 1153 UHF Reader 
configuration and restore to defaults 
if unsure. 
The orange LED flashes rapidly 
when charging. 
There is a battery fault.
Replace the battery pack.
The battery pack temperature is 
outside recommended limits.
Ensure that charging only occurs 
between 5°C and 40°C. 
The host 
Bluetooth
®
 discovery does 
not find the 1153 UHF Reader. 
The 1153 UHF Reader has powered 
off.
Press the yellow button and ensure 
the blue LED is flashing.
The 1153 UHF Reader is out of 
range.
Move the 1153 UHF Reader closer 
to the host.
The 
Bluetooth
®
 friendly name of 
the 1153 UHF Reader has been 
changed.
Check the 
Bluetooth
®
 friendly name 
or restore the 1153 UHF Reader to 
factory defaults if unsure.
Opening the 
Bluetooth
®
 virtual com 
port does not connect to the 1153 
UHF Reader.
The host has paired to a different 
Bluetooth
®
 device.
Pair to the required 1153 UHF 
Reader.
The host 
Bluetooth
®
 function has an 
error.
Warm boot the host. If this does not 
help, delete the 1153 UHF Reader 
from the favourites list and re-pair.
Bluetooth
®
 pairing fails.
The PIN on the 1153 UHF Reader 
has been changed
Set the 
Bluetooth
®
 PIN to a known 
value
www.tsl.uk.com