Sena Technologies Inc. PARANISD1100 Manuel D’Utilisation

Page de 48
 11
2.2. LED Indicators 
 
RS422/485-Tx and RS422/485-Rx LED will flash accordingly when data is transmitted. For small data 
transmissions, it may be hard to recognize the quick flashing action of the LED. Charge Led and Low 
battery LED will be off, if you don’t use battery pack. 
 
Table 2-2 The Parani-SD1100 LED Indicators 
Indicator 
Power LED 
Standby LED 
Connect LED 
Indicator 
Mode0 
Green   ┏━━━━━
Red     
┏━━━━━
 
 
Mode0
 
Mode1 
Green   ┏━━━━━
 
Green (every 1 
sec)  ┏┓ 
Mode1
 
Mode2 
Green   ┏━━━━━
 
Green (every 3 
sec)  ┏┰┓ 
Mode2
 
Mode3 
Green   ┏━━━━━
 
Green (every 3 
sec)  ┏┰┓ 
Mode3
 
Connected 
Green   ┏━━━━━ 
 
Green   
┏━━━━━━━
 
Connected
 
Indicator Power 
LED
 
Standby LED
 
Connect LED
 
Indicator
 
Mode0 
Green   ┏━━━━━ 
Red     
┏━━━━━
 
 
Mode0
 
Mode1 
Green   ┏━━━━━ 
 
Green (every 1 
sec)  ┏┓
 
Mode1
 
 
 
2.3. Serial Ports 
 
The applicable settings for serial ports are as follows. 
 
Table 2-3 The Parani-SD1100 Serial Port Settings 
Serial Port Settings 
Values 
Baud rate 
1200, 2400, 4800, 9600, 14400, 19200, 38400, 57600, 115200, 230400, 460800, 
921600 
Data bite 
Parity 
No parity, Even parity, Odd parity 
Stop bit 
1, 2 
Hardware Flow Control 
No Use 
 
The values in box are the factory defaults.   
 
2.4. Data Bit 
 
Parani-SD1100 supports only 8 data bit. In the case of 7 data bit and even/odd parity, use 8 data bit 
and none parity. At this time, master and slave are Parani-SD, Parani-ESD or Parani-MSP series. But 
7 data bit and none parity is not support.