EXTERNAL CORE NODE INSTALLATION / REFERENCE GUIDE
Environmental Considerations
Operational Temperature: -30°C - +55°C (-22°F - 131°F)
Storage Temperature: -50°C - +65°C (-58°F - 149°F)
Ingress Protection Rating:
External Core Node - IP43 Compliant
External Sensor Pod
External Sensor Pod
– IP65 Compliant
Required Tool List
Flat Head Screwdriver
Cable De-Latching Tool
UV resistant outdoor cable ties
Power, Current and Weight Requirements
Voltage Configuration
Switchable LED Power (Watts)
Switchable LED Current (A)
Switchable AUX Current (A)
Maximum Weight (lbs.)
120V
600
5
2
1.0
277V
831
3
2
1.0
480V
480
1
1
1.5
External Sensor Pod Pole Mounting Requirements
Mounting Type
Horizontal Pole Mount
Vertical Pole Mount
Round Pole Diameter
1 5/8” – 2 3/8”
Minimum 3”
Square Pole Dimension
Minimum 4” height
Minimum 3” width
Installation Preparation
1.
Ensure the luminaire fixture is equipped with acceptable 7-pin NEMA connector. If fixture does not have this receptacle, a retrofit kit can be
ordered from Sensity Systems.
ordered from Sensity Systems.
2.
Ensure NEMA receptacle North Position (N) is orientated 90° right of luminaire (3 o’clock position) if faced from pole direction. This ensures
the External Core Node power connection is correctly facing the pole-side of the luminaire.
the External Core Node power connection is correctly facing the pole-side of the luminaire.
Mounting Instructions
Pole Mounting illustration is shown. Box arm mounting instructions are same, substituting pole for box arm following mounting requirement size above.
1.
Install the External Core Node on the photocell receptacle by fully seating the node prongs in to the receptacle, provide a slight clockwise twist
to lock into place.
to lock into place.
Optional External Sensor Pod Installation
1.
External Sensor Pod includes (1) Horizontal Bracket and (1) Vertical Bracket for mounting. Chose what is best suited for installation and
discard other.
discard other.
2.
Position External Sensor Pod at the distance provided by the included sensor power cable.
3.
Using supplied band-clamp, feed strap through mounting tabs and secure to intended pole location.
4.
Tighten clamp until sensor bracket is firm and secure.
5.
Position External Sensor Pod onto mounting bracket and secure with wingnuts. No not over-tighten.
Sensor should be facing in a downward position for optimal performance.
Sensor should be facing in a downward position for optimal performance.
6.
Remove protective cap from the External Core Node power tap using supplied De-Latching tool
7.
Install supplied sensor cable into mating connectors on both External Core Node and External Sensor Pod. Ensure a positive snap is heard,
noting positive connector engagement.
noting positive connector engagement.
8.
Secure all power cables to pole using UV rated cable ties. Refer to local and national codes for additional clarification and laws.
SAFETY PRECAUTIONS / INSTALLATION CONSIDERATIONS
Installation and service should be performed by a qualified licensed electrician.
All electrical work should be completed by a licensed electrical contractor.
Installation should conform to all national and/ or local municipal laws and codes.
Disconnect or safe-off all power before installation.
DO NOT INSTALL DAMAGED PRODUCT! This External Core Node and External Sensor Pod has been properly packed so that no parts should
have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection
with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered
sufficiently for the purchaser’s or owner’s purposes, please contact Sensity Systems directly.
sufficiently for the purchaser’s or owner’s purposes, please contact Sensity Systems directly.
Installation is inte
nded for outdoor luminaires. Product should not be installed ≤20ft from ground level and must be considered out of reach from
normal access.