EXTERNAL CORE NODE INSTALLATION / REFERENCE GUIDE 
 
Environmental Considerations 
 
Operational Temperature: -30°C - +55°C (-22°F - 131°F) 
 
Storage Temperature: -50°C - +65°C (-58°F - 149°F) 
 
Ingress Protection Rating:  
External Core Node - IP43 Compliant 
External Sensor Pod 
– IP65 Compliant 
 
 
Required Tool List 
 
Flat Head Screwdriver 
 
Cable De-Latching Tool 
 
UV resistant outdoor cable ties 
 
 
Power, Current and Weight Requirements 
Voltage Configuration 
Switchable LED Power (Watts) 
Switchable LED Current (A) 
Switchable AUX Current (A) 
Maximum Weight (lbs.) 
120V 
600 
1.0 
277V 
831 
1.0 
480V 
480 
1.5 
 
 
External Sensor Pod Pole Mounting Requirements 
Mounting Type 
Horizontal Pole Mount 
Vertical Pole Mount 
Round Pole Diameter 
1 5/8” – 2 3/8” 
Minimum 3” 
Square Pole Dimension 
Minimum 4” height 
Minimum 3” width 
 
 
Installation Preparation 
1. 
Ensure the luminaire fixture is equipped with acceptable 7-pin NEMA connector.  If fixture does not have this receptacle, a retrofit kit can be 
ordered from Sensity Systems. 
2. 
Ensure NEMA receptacle North Position (N) is orientated 90° right of luminaire (3 o’clock position) if faced from pole direction.  This ensures 
the        External Core Node power connection is correctly facing the pole-side of the luminaire. 
 
Mounting Instructions 
Pole Mounting illustration is shown.  Box arm mounting instructions are same, substituting pole for box arm following mounting requirement size above. 
 
1. 
Install the External Core Node on the photocell receptacle by fully seating the node prongs in to the receptacle, provide a slight clockwise twist 
to lock into place. 
 
Optional External Sensor Pod Installation 
1. 
External Sensor Pod includes (1) Horizontal Bracket and (1) Vertical Bracket for mounting.  Chose what is best suited for installation and 
discard other. 
2. 
Position External Sensor Pod at the distance provided by the included sensor power cable.   
3. 
Using supplied band-clamp, feed strap through mounting tabs and secure to intended pole location.   
4. 
Tighten clamp until sensor bracket is firm and secure. 
5. 
Position External Sensor Pod onto mounting bracket and secure with wingnuts.  No not over-tighten.  
Sensor should be facing in a downward position for optimal performance. 
6. 
Remove protective cap from the External Core Node power tap using supplied De-Latching tool 
7. 
Install supplied sensor cable into mating connectors on both External Core Node and External Sensor Pod.  Ensure a positive snap is heard, 
noting positive connector engagement. 
8. 
Secure all power cables to pole using UV rated cable ties.  Refer to local and national codes for additional clarification and laws. 
 
 
 
 
SAFETY PRECAUTIONS / INSTALLATION CONSIDERATIONS 
 
 Installation and service should be performed by a qualified licensed electrician. 
 All electrical work should be completed by a licensed electrical contractor.  
 Installation should conform to all national and/ or local municipal laws and codes.  
 Disconnect or safe-off all power before installation.  
 DO NOT INSTALL DAMAGED PRODUCT! This External Core Node and External Sensor Pod has been properly packed so that no parts should 
have been damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.  
 These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection 
with installation, operation, or maintenance. Should further information be desired or should particular problems arise which are not covered 
sufficiently for the purchaser’s or owner’s purposes, please contact Sensity Systems directly. 
 Installation is inte
nded for outdoor luminaires.  Product should not be installed ≤20ft from ground level and must be considered out of reach from 
normal access.