Settings Tab
Impact Hard Threshold (G)
Threshold for hard impact detection for the vehicle (hard
impacts have greater intensity and shorter duration). See
“RECOMMENDED SETTINGS”.
impacts have greater intensity and shorter duration). See
“RECOMMENDED SETTINGS”.
Impact Hard Samples
Number of samples measured for hard impact detection for the
vehicle. See “RECOMMENDED SETTINGS”.
vehicle. See “RECOMMENDED SETTINGS”.
Impact Soft Threshold (G)
Threshold for soft impact detection for the vehicle (soft
impacts have lesser intensity and longer duration). See
“RECOMMENDED SETTINGS”.
impacts have lesser intensity and longer duration). See
“RECOMMENDED SETTINGS”.
Impact Soft Samples
Number of samples measured for soft impact detection for the
vehicle. See “RECOMMENDED SETTINGS”.
vehicle. See “RECOMMENDED SETTINGS”.
(Impact) Lift Interrupt
From Authorization Group settings. Yes for Lift Interrupt
when Impact is detected. No for no Lift Interrupt when
Impact is detected.
when Impact is detected. No for no Lift Interrupt when
Impact is detected.
(Impact) Secondary Alarm
From Authorization Group settings. Yes for Secondary Alarm
when Impact is detected. No for no Secondary Alarm when
Impact is detected.
when Impact is detected. No for no Secondary Alarm when
Impact is detected.
(Impact) Interrupt/Alarm Delay
(seconds)
(seconds)
From Authorization Group settings. Number of seconds
before Lift Interrupt or Secondary Alarm engages when
Impact is detected.
before Lift Interrupt or Secondary Alarm engages when
Impact is detected.
(Impact) Automatic Reset
From Authorization Group settings. Yes if Automatic Reset
occurs when Impact is detected.
occurs when Impact is detected.
Hour Meter at Installation
Vehicle hour meter reading when Vehicle equipped with a G
FORCE PLUS/RF Vehicle Monitor is put into service.
FORCE PLUS/RF Vehicle Monitor is put into service.
G FORCE Hour Meter
G FORCE PLUS/RF Vehicle Monitor Hour Meter reading
determined by PM Time Tracking Method.
determined by PM Time Tracking Method.
Actual Vehicle Hours
Addition of values from Hour Meter at Installation and G
FORCE Hour Meter.
FORCE Hour Meter.
Date of Last PM
The most recent date of a Maintenance Work Order identified
with a Scheduled PM reason. If no Maintenance Work Orders
are entered, this field will remain blank.
with a Scheduled PM reason. If no Maintenance Work Orders
are entered, this field will remain blank.
Next PM Due in (hours)
Number of hours that the next scheduled PM is due for the
Vehicle.
Vehicle.
PM Time Tracking Method
From Authorization Group settings. Method of tracking time
for scheduled Preventative Maintenance purposes: Login or
Motion.
for scheduled Preventative Maintenance purposes: Login or
Motion.
PM Interval/Frequency every (hours)
From Authorization Group settings. Value used to update
when the next scheduled Preventative Maintenance should be.
when the next scheduled Preventative Maintenance should be.
Battery Nominal Voltage
Nominal battery voltage for the Vehicle.
OK To Charge Threshold
Upper limit of the OK To Charge battery range in specific
gravity points.
gravity points.
Must Charge Threshold
Upper limit of the Must Charge battery range in specific