Hitachi Kokusai Electric Inc. SL24G-US-02 Manuel D’Utilisation

Page de 108
5. Performing Maintenance From TELNET
 
5-8 SNMP settings
 
 
70 
 
5-8-5
 
Setting the sysName 
Input format: 
snmp    sysname    sysName 
no    snmp    sysname 
Input options 
sysName 
sysName: 1 to 255 single-byte alphanumeric characters or symbols. 
(Default value: Not set) 
Executing user 
Administrator 
Operation: 
Sets the sysName. 
To delete the sysName, add "no" to the beginning of the line. 
 
 
 
5-8-6
 
Setting the sysLocation 
Input format: 
snmp    syslocation    sysLocation 
no    snmp    syslocation 
Input options 
sysLocation 
sysLocation: 1 to 255 single-byte alphanumeric characters or symbols. 
(Default value: Not set) 
Executing user 
Administrator 
Operation: 
Sets the sysLocation. 
To delete the sysLocation, add "no" to the beginning of the line. 
 
 
 
5-8-7
 
Setting the linkUp trap 
Input format: 
snmp    trap    linkup    switch 
Input options 
switch 
Enables/disables the linkUp trap: (default value: enable) 
enable 
Enables the linkUp trap 
disable 
Disables the linkUp trap 
Executing user 
Administrator 
Operation: 
Sets the enabling/disabling of sending linkUp traps. 
 
 
 
5-8-8
 
Setting the linkDown trap 
Input format: 
snmp    trap    linkdown      switch 
Input options 
switch 
Enables/disables the linkDown trap: (default value: enable) 
enable 
Enables the linkDown trap 
disable 
Disables the linkDown trap 
Executing user 
Administrator 
Operation: 
Sets the sending of linkDown traps. 
 
 
 
5-8-9
 
Setting the AuthenticationFailure trap 
Input format: 
snmp    trap    authenfailure    switch 
Input options 
switch 
Enables/disables the Authentication Failure trap: (default value: enable) 
enable 
Enables the AuthenticationFailure trap 
disable 
Disables the AuthenticationFailure trap 
Executing user 
Administrator 
Operation: 