Hitachi Kokusai Electric Inc. SL24G-US-02 Manuel D’Utilisation
5. Performing Maintenance From TELNET
5-8 SNMP settings
70
5-8-5
Setting the sysName
Input format:
snmp sysname sysName
no snmp sysname
no snmp sysname
Input options
sysName
sysName: 1 to 255 single-byte alphanumeric characters or symbols.
(Default value: Not set)
(Default value: Not set)
Executing user
Administrator
Operation:
Sets the sysName.
To delete the sysName, add "no" to the beginning of the line.
To delete the sysName, add "no" to the beginning of the line.
5-8-6
Setting the sysLocation
Input format:
snmp syslocation sysLocation
no snmp syslocation
no snmp syslocation
Input options
sysLocation
sysLocation: 1 to 255 single-byte alphanumeric characters or symbols.
(Default value: Not set)
(Default value: Not set)
Executing user
Administrator
Operation:
Sets the sysLocation.
To delete the sysLocation, add "no" to the beginning of the line.
To delete the sysLocation, add "no" to the beginning of the line.
5-8-7
Setting the linkUp trap
Input format:
snmp trap linkup switch
Input options
switch
Enables/disables the linkUp trap: (default value: enable)
enable
enable
Enables the linkUp trap
disable
Disables the linkUp trap
Executing user
Administrator
Operation:
Sets the enabling/disabling of sending linkUp traps.
5-8-8
Setting the linkDown trap
Input format:
snmp trap linkdown switch
Input options
switch
Enables/disables the linkDown trap: (default value: enable)
enable
enable
Enables the linkDown trap
disable
Disables the linkDown trap
Executing user
Administrator
Operation:
Sets the sending of linkDown traps.
5-8-9
Setting the AuthenticationFailure trap
Input format:
snmp trap authenfailure switch
Input options
switch
Enables/disables the Authentication Failure trap: (default value: enable)
enable
enable
Enables the AuthenticationFailure trap
disable
Disables the AuthenticationFailure trap
Executing user
Administrator
Operation:
Sets the enabling/disabling of sending AuthenticationFailure traps.