Spotwave Wireless Ltd. SPOTCELL0006 Manuel D’Utilisation

Page de 50
I
NSTALLATION
8
SpotCell 100, Release 1.0
3.1.3 Avoid obstructions
General placement of the DU and CU must be in unobstructed areas. 
For example, the CU should not be placed on a wall behind any type of 
furniture (behind items such as metal filing cabinets would be a 
particularly poor location). Similarly for the DU, the front of the unit 
should not be directly facing any type of metal structures, which are 
often found on building rooftops.
3.1.4 Proximity to power source
The indoor unit must be located within 20 feet of a power source. 
3.1.5 Distance between DU and CU
Although you should separate the DU and CU as much as possible, 
there are only 25 meters of cabling provided to connect the two units. 
Make sure the general location of the two units is within 25 meters. 
Note: An additional cable extension, made from copper core RG6 quad 
shield cable, may be inserted, to a maximum of 50 meters total length.
3.1.6 Orientation of DU relative to CU
If possible face the DU and CU in opposite directions, and back to back 
while maintaining maximum separation. While not a requirement, some 
installations will perform better if the units are positioned in this 
manner.
3.1.7 Barrier between DU and CU
The greater the physical obstruction between the DU and CU, the 
better the performance. Dense obstructions such as brick, concrete or 
metal walls are better than wooden or plaster walls.
3.2 Positioning the SpotCell DU (outward facing unit) 
It may not be possible to install the DU indoors when installing the 
SpotCell in remote areas. An effort should be made to install the DU 
outdoors and the DU should be installed as high as possible when the 
installation is in a remote area,